NORSOK STANDARD
PIPING AND EQUIPMENT INSULATION
R-004
Rev. 2, June 1999
This NORSOK standard is developed by NTS with broad industry participation. Please note that whilst every effort has been made to ensure the accuracy of this standard, neither OLF nor TBL or any of their members will assume liability for any use thereof. NTS is responsible for the administration and publication of this standard.
Norwegian Technology Standards Institution
Oscarsgt. 20,
Postbox 7072 Majorstua
N-0306 Oslo, NORWAY
Telephone: + 47 22 59 01 00 Fax: + 47 22 59 01 29
Email:
nts@nts.no Website: http://www.nts.no/norsok
Copyrights
reserved
CONTENTS
1 SCOPE
3 DEFINITIONS AND ABBREVATIONS
3.1 Definitions
3.3 Abbreviations
4.1 Introduction
4.2 Design
4.3 Materials
4.4 Installation
5 HOT SERVICE AND ACOUSTIC INSULATION
5.1 General
5.2 Design
5.3 Installation
5.4 Guidance for insulation thickness
6.1 General
6.2 Design
6.3 Installation
7 COMBINATION OF INSULATION CLASSES
7.1 General
7.2 Acoustic insulation (6, 7 & 8) combined with Heat conservation (1) or Personnel protection (3)
7.3 Fire Proofing (5) combined with cold service insulation (2, 4 and 9)
7.4 Acoustic insulation (6, 7 & 8) combined with cold service insulation (2, 4 and 9)
8.1 Qualification of insulation system
ANNEX A - KEY DATA
FOR INSULATION SYSTEMS
ANNEX B - INSERTION
LOSS - TEST PROCEDURE
NORSOK (The competitive standing of the Norwegian offshore sector) is the industry initiative to add value, reduce cost and lead time and eliminate unnecessary activities in offshore field developments and operations.
The NORSOK standards are developed by the Norwegian petroleum industry as a part of the NORSOK initiative and supported by OLF (The Norwegian Oil Industry Association) and TBL (Federation of Norwegian Engineering Industries). NORSOK standards are administered by NTS (Norwegian Technology Standards Institution).
The purpose of NORSOK standard is to contribute to meet the NORSOK goals, e.g. by replacing the individual oil company specifications and other industry guidelines and documents for use in existing and future petroleum industry developments.
The NORSOK standards make extensive references to international standards. Where relevant, the contents of a NORSOK standard will be used to provide input to the international standardisation process. Subject to implementation into international standards, this NORSOK standard will be withdrawn.
The revision 2 of this standard is updated and partly rewritten from industry experience over the last years. Materials have been given a broader presentation. A new section is added on Qualification Requirements, addressing requirements to insulation systems, procedures and qualification of personnel.
1. SCOPE
This standard covers the minimum requirements for thermal, acoustic, personnel protection and fireproofing insulation of pipe work and equipment for offshore / onshore installations.
This standard does not cover insulation of HVAC related items, see NORSOK Standard H 002 Piping and plumbing.
2. REFERENCES
2.1 Normative references
| API RP 521 | Guide for Pressure Relieving and De-pressuring Systems |
| ASTM-C552 | Cellular Glass Block and Pipe Thermal Insulation. |
| ASTM-C592 | Mineral Fibre Blanket Insulation and Blanket Type Pipe insulation |
| ASTM-C303 | Test method for Density of Pre formed Block-Type Thermal Insulation |
| ASTM-C177 | Test method for Steady-State Heat Flux Measurement |
| ASTM-165 | Test Method for Measuring Compressive Properties of Thermal Insulation |
| ASTM-D3833 | Test Method for Water Vapour Transmission of Tapes |
| ASTM-G53 | Practise for Operating Light- and Water-Exposure of Non - metallic materials |
| EN 253 : 1994 | Pre-insulated bonded pipe systems for underground hot water networks |
| IMO Resolution | A.653 (16 ) Recommendations on Improved Fire Test procedures for Surface Flammability of bulkhead, Ceiling and Deck Finish Materials |
| ISO 834 | Fire resistance tests Elements of building constructions |
| ISO 5660 | Fire tests Reaction to Fire Rate of Heat Release from Building Products |
| NORSOK S-002 | Working Environment |
| NORSOK M-501 | Surface Preparation and Protective Coating |
| NT Fire 036 | Pipe Insulation: Fire spread and smoke production Full scale test |
| OTO 93028 | Jet fire Test |
2.2 Informative references
| AGR EmiTeam | Insulation Handbook. |
| Established in 1999 by Statoil, Norsk Hydro and Saga |
3. DEFINITIONS AND ABBREVATIONS
3.1 Definitions
| NORSOK | Norsk Sokkels Konkurranseposisjon, the Competitive standing of the Norwegian Offshore Sector, the Norwegian initiative to reduce cost on Offshore projects. |
| Functional specification | As defined in ISO 13879 and ISO 13880: Document that specifies the requirements expressed by features, characteristics, process conditions, boundaries and exclusions defining the performance of the product, process or service.. |
| Technical specification | As defined in ISO 13879 and ISO 13880: Document that prescribes technical requirements to be fulfilled by the product, process or service in order to comply with the functional specification. |
| Normative references | Shall mean normative (a requirement ) in the application of NORSOK Standards. |
| Informative references | Shall mean informative in the application of NORSOK Standards. |
| Shall | Verbal form used to indicate requirements strictly to be followed in order to conform to the standard and from which no deviation is permitted, unless accepted by all involved parties. |
| Should | Verbal form used to indicate that among several possibilities one is Recommended as particularly suitable, without mentioning or Excluding others, or that a certain course of action is preferred but Not necessarily required. |
| May | Verbal form used to indicate a course of action permissible within the limits of the standard. |
| Can | Verbal form used for statements of possibility and capability, Whether material, physical or casual. |
3.2 Insulation classes
Heat conservation Class 1
The purpose is to reduce heat losses and to maintain temperatures for the efficient operation of the process.
Cold medium conservation Class 2
The purpose is to maintain low temperature and control heat input to the process.
Personnel protection Class 3
Surfaces with operating temperatures below -10 ° C or above 70 ° C and are confined to a distance of not more than 2,1 m vertically and 0,8 m horizontally away from walkways and normal working areas shall be guarded by screens. Insulation shall only be used where guards are not practical.
Frost proofing Class 4
Insulation/heat tracing to prevent freezing, solidification and condensation.
Fire proofing Class 5
The purpose is to reduce the heat input and limit the temperature to 400 ° C on piping, vessels and equipment in a hydrocarbon fire situation lasting for 30 minutes according to ISO 834.
Fire proofing according to any other fire scenarios shall be specified in each project. Selected fire proofing shall be documented and if necessary fire tested.
Acoustic insulation Class 6, 7 and 8
The acoustic insulation is defined as the arithmetic average of the insertion loss in the three octaves bands 500 Hz, 1000 Hz and 2000 Hz.
Based on documented insertion loss, each project may select materials or combinations of materials to cover the required insertion loss at actual frequencies. Ref. Annex 2 "Insertion loss Test procedure" for this Standard. This selection shall not conflict with any other requirement of this standard, and Company shall approve each combination.
Valves and flanges shall be insulated when and as required by Company.
Acoustic insulation Class 6
Reduction of noise in the area 500-2000 Hz by 10 dB.
Acoustic insulation Class 7
Reduction of noise in the area 500-2000 Hz by 20 dB.
Acoustic insulation Class 8
Reduction of noise in the area 500-2000 Hz by 30 dB.
External condensation and icing protection Class 9
The purpose is to prevent condensation on piping and equipment with operation temperatures below ambient.
For combination of insulation classes see clause 7.
3.3 Abbreviations
| AISI | American Iron and Steel Institute |
| ASTM | American Society for Testing and Materials |
| DN | Diameter Nominal |
| EN | European Norm |
| HSE | Health, Safety and Environment |
| IMO | International Maritime Organisation |
| ISO | International Organisation of Standardisation |
| NT | Nordtest |
| P&ID | Piping & Instrument Diagram |
4. GENERAL REQUIREMENTS
4.1 Introduction
General requirements for thermal insulation (hot and cold) are given in this clause. Specific requirements for hot service and acoustic insulation are stated in clause 5, and cold service insulation in clause 6.
Pre insulated piping may be used in relevant classes.
Alternative insulation may be used if the proposed materials and methods satisfy the functional requirements in this specification. Approval by Company is required.
4.2 Design
4.2.1 General
Piping and equipment shall be insulated according to the insulation class, operating temperature and insulation thickness stated in the P&ID and Data sheets.
All insulation shall be covered with weather protection designed and installed to prevent ingress of water during normal operation throughout the design life.
Insulation adjacent to flanges in piping and equipment shall be terminated to allow removal of bolts without damage to insulation. Minimum free space from the flange to the nearest part of the insulation shall be equal to the bolt length +25 mm. The termination of the weather protection shall be waterproof.
When a rigid type of insulation is used, provision shall be made for longitudinal expansion and contraction.
4.2.2 Vessel insulation
Insulation of all vessels shall be supported on rings with a distance of 900 mm c/c installed on the vessel. Rings shall also be provided around nozzles above DN 200 mm.
Block insulation shall be fastened with mechanically tightened metal bands or with bonding adhesive.
Insulation on vessel heads shall be fastened with bands spaced not more than 300 mm centres. The bands shall be fixed to the fixing ring installed on the vessel.
Vessels of diameter 1500 mm and smaller shall be insulated as piping.
4.2.3 Removable insulation of flanges and valves
Removable insulation for flanges and valves, like tailor made jackets or pre
formed insulation boxes, shall be suitable for quick removal and
reinstallation.
All tailor made jackets shall fit the actual
valve/flange/equipment and secure adequate overlap to incoming insulated
pipes.
4.2.3.1 Outer material of tailor made jackets
The outer material shall be silicone rubber proofed fabric made from glass fiber. Other materials may be used provided that the material properties can be documented to be equal or better than silicone rubber.
The material shall be suitable for use against temperatures between -30 oC and +230 oC.
The silicone rubber coating shall prevent water being absorbed by the
insulation material.
The outer material shall be non-combustible or at least
self-extinguishing, and tested according to IMO Resolution A.653 (16) or
similar.
The sewing thread shall be stainless steel reinforced cevlar thread
and shall be suitable within the same temperatures as the woven glass fiber
fabric. The sewing thread shall not resolve or decompose in typical offshore
environment.
4.2.3.2 Insulation in fill materials of tailor made jackets
The insulation in-fill materials shall be a flexible mat of mineral fiber having a density according to insulation class, foil faced on one side.
Precautions must be implemented in the design and fabrication of the insulation jackets to avoid the insulation material from sagging causing reduction of the insulation properties of the jackets.
The insulation material shall be non-combustible.
The thickness of insulation shall be 25 mm for DN 80 pipes or smaller, and 50 mm for diameter DN 100 pipes and larger.
Other insulating materials may be used provided they have the same or better properties. Insulation thickness of other insulation materials shall be based on calculation of thermal conductivity and insulation class.
4.2.3.3 Water ingress and drainage
The design of the tailor made jackets shall be deluge proof.
Each tailor made jacket shall be provided with a hole for drainage at it's lowest point. The drainage hole shall be installed in such a manner that water cannot enter into the internals of the cover and saturate the insulating fiber.
The drainage holes shall have silicone mastic between the reinforced ring and the silicone rubber sheets on both sides of the jacket.
4.2.3.4 Locking Mechanism for tailor made jackets
The locking mechanism of the tailor made jackets shall be of the velcroues flap fastener type. In exposed area the tailor made jacket shall be fastened to the pipe by stainless steel bands. The fastener type used shall be proven through experience. Minimum width shall be 100 mm for jackets applied on valves/flanges larger than DN 80, and 50 mm for jackets applied on valves/flanges DN 80 and smaller.
4.2.3.5 Metallic Parts
Any metallic parts in the design of the tailor made jackets shall be of stainless steel of quality AISI 316 or better. Grommets for reinforcing drain holes may be of brass.
4.2.3.6 Resistance against different media
The outer material shall be resistant against diluted chemicals, detergents and hydrocarbons.
4.2.3.7 Identification of tailor made jackets
Each removable insulation cover shall be provided with an identification plate with the following information:
- Vendor name
- Line number
- Tag number
- Cover number
-
Certificate number
The vendor shall also identify each cover on drawings and store this information according to the vendor quality system.
The identification number system shall be easily read prior to and after installation and shall be placed under the flap fastener. The identification plate shall be made of a material resistant to water and/or chemicals.
The numbering system for identification of individual cover shall be provided by Company after contract award.
4.2.4 Insulation of instrument and instrument tubing
For insulation of instruments, insulated cabinets with hinged doors shall be used. Instrument tubing of max DN 25 may be insulated with cellular rubber for temperatures up to 100 OC. For temperatures above 100 OC, glass fibre rope and jacketing may be used.
4.2.5 Piping insulation
Insulation on long vertical pipe runs shall be supported on rings spaced on 6400 mm maximum centres installed on the piping. Width of rings shall be half the thickness of the insulation material.
4.2.6 Metallic jacketing
Flat heads are not allowed on top of vertical vessels.
Removable insulation covers shall be provided for removable vessels heads.
The bottom heads of skirt supported vessels may be covered with flat metallic jacketing.
Jacketing for flanges and valves shall be formed such that it sheds water.
Longitudinal seams of metal jackets on horizontal or sloping pipelines shall be located maximum 60 degrees away from the lowest point of the circumference.
All seams on metallic jacketing shall be provided with a metal seam sealant to become water proof.
4.2.7 Non metallic jacketing
For pipe insulation a non-metallic weather protection may be used instead of metallic jacketing for all classes except class 5. Fire proofing. The non metallic weather protection must fulfil the requirements in clause 4.3.7 and be verified with tests. Use of combustible non metallic jacketing in enclosed areas shall be subject of approval in writing with regard to HSE aspects.
It is recommended to apply aluminium foil between cellular glass and the non metallic jacketing.
4.2.8 Heat traced piping
Heat traced piping shall be wrapped with 0,05 mm aluminium foil prior to insulation to protect the heating cables and improve the heat distribution.
Where heating cables penetrate the jacketing, edge protection shall be provided to prevent damage to the cable. A permanent sealer shall be applied in order to prevent ingress of water.
4.2.9 Drains
For all insulation systems and insulation classes for piping and equipment (except for class 2, 5 and 9) there shall be 15 mm diameter drain holes in all low points, and a minimum of one hole every 3 metres on horizontal runs.
Compact pre-insulated piping system does not require low point drain.
4.3 Materials
4.3.1 General
Insulation materials for classes 1, 2, 3, 4, and 9 shall consist of cellular glass. Materials for class 5, 6, 7 and 8 shall be cellular glass in combination with mineral wool, mineral fibre or ceramic fibres.
All insulation materials shall have a neutral pH value.
Insulation concept shall be non combustible, non-toxic and water tight/water repellent. The materials shall not release toxic or corrosive gases when exposed to fire. No asbestos or asbestos products shall be used. No lead or lead products shall be used unless accepted by company.
These requirements are not applicable to pre-insulated pipe systems.
In dry rooms where no sprinkler deluge system exist mineral wool may be used on pipes/vessels with an operating temperature above +40 OC. Indoor areas with regular water cleaning or testing of sea-water deluge system are not considered dry. The system shall have drain holes according to clause 4.2.9.
For steam and exhaust pipe, mineral wool may be used with stainless steel jacketing.
Mineral wool shall under no circumstances be applied on stainless steel materials like AISI 316, duplex, 6Mo etc.
4.3.2 Fire insulation materials
The material shall withstand relevant temperatures while maintaining its fire protection properties. For jet fire protection high duty fibres that withstand temperatures above 1150 OC shall be considered.
4.3.3 Cellular glass
Cellular glass shall have the following properties:
Conform to ASTM C552 and be suitable for temperatures from 260 OC to 430
OC
The density shall be within 125 kg/m3 +/- 10 % as per ASTM C303
Thermal
conductivity, not greater than 0,0039 W/mK as per ASTM C177
Average
compressive strength per ASTM C165: 490 kPa
Water vapour transmission:
Zero
Linear expansion coefficient: 8,5 x 10-6/ OC
4.3.4 Mineral wool
Mineral wool shall be manufactured with a phenol binder. The specific flow resistance for the mineral wool shall be minimum 2,0 x 10 4 Pa s/m 2 .The density shall be within 90-120 kg/m 3
4.3.5 Sealers, Tape
Joint sealers and tape shall be permanently flexible through a relevant temperature range and shall be capable of withstanding repeated expansion and contraction.
4.3.6 Metallic jacketing
Metallic jacketing shall be stainless steel or sea water resistant Al-alloy. For fire protection the jacketing material shall be stainless steel.
4.3.6.1 Stainless steel
Stainless steel metal jacketing
shall be type AISI 316, 2B finish.
Stainless steel sheets for pipes and
vessels up to DN 450 shall have a thickness of 0,5 mm. For dimensions above DN
450 the thickness shall be 0,7 mm.
4.3.6.2 Aluminium alloy
Aluminium alloy jacketing shall
be type A1Mn1 (AA 3103) or equal.
Aluminium sheets for pipes and vessels up
to DN 450 shall have a thickness of 0,7 mm. For dimensions above DN 450 the
thickness shall be 0,9 mm.
4.3.7 Non metallic jacketing
4.3.7.1 Fire characteristics incl. Smoke and toxic
gases
According to ISO 5660 and additional techniques. No additional
acceptable amounts of smoke/fumes beyond what is produced in a HC fire. In
addition to what ISO 5660 specifies, concentration of various vapours, fumes and
gases shall be documented according to the chemical composition of the material.
Based on these tests the material can be subject to application
restrictions.
Flame spread as per IMO Res. A.653 (16) equal to self
extinguishing properties.
4.3.7.2 Weathering/durability.
500 hours
Weather-O-meter testing according to ASTM G53 incl. wet/dry-cycling.
(UV-B313).
Less than 70 % loss of lustre. The material shall maintain 90 % of
its strength properties after the Weather-O-meter test.
4.3.7.3 Material parameters
Water vapour transmission:
10g/m /24h as per ASTM D3833.
Mechanical properties:
Min. Tensile strength 6.9 MPa (1000
psi).
Elongation at break min.10 %.
The material shall not decompose at
temperatures from 20 OC to 70 OC .
Any possible shrinkage or temperature
unsuitability of the tape material shall be documented.
4.3.7.4 Application
The tape material shall be suitable
for application at RH up to 90 % and down to +5 OC . New materials shall be
subject to a pilot test for verification of the application performance.
4.3.7.5 General
Storage stability of the tape shall be
minimum 6 months.
Technical specifications and HSE data sheets shall be in
Norwegian.
Types of non-metallic weather proofing shall be subject to Company
approval.
4.3.8 Bonding adhesive
For temperatures
up to 140 OC adhesive shall be used for bonding of insulation to vessels. When
the adhesive cures it shall constitute a flexible bond that absorbs mechanical
and thermal stress.
Bonding adhesive shall not be used above 140 OC.
4.3.9 Anti-abrasive coating
The high
temperature anti-abrasive coating may be a high strength gypsum cement with
inert mineral fillers applied on the inner surface of the insulation sections.
When dry, the cement shall form a hard surface protection against
abrasion.
Anti-abrasive coating shall be used to prevent damage to cellular
glass and painting due to vibration where applicable.
The low temperature
anti-abrasive coating shall be a one component urethane based coating.
The
anti-abrasive coating shall be suitable for application at service
temperatures.
4.3.10 Metallic foils
Aluminium foils
as an initial wrapping over heat traced piping and equipment shall be soft
temper foil, 0,05 mm thick.
If heat tracing is used to any type of stainless
steel piping, then aluminium foil with polyester on one side shall be
used.
The polyester coated side to be applied towards the pipe to prevent
galvanic corrosion.
4.3.11 Accessories
Vendor to specify
standard (material, dimension, type) regarding accessories such as rivets,
toggle latches, bands, wires, clips, breather springs etc. all in AISI 316
materials.
4.3.12 Pre-insulated pipe systems
Pre-insulation shall consist of an insulation layer and a watertight outer
jacket. Dimension of outer jacket shall be in accordance with EN 253: Casing
pipe dimensions.
The insulation system must withstand minimum 0,3 MPa
pressure to the outer surface. It must be designed for clamping on the outer
jacket or water tight insulation of supports.
Field insulation of field
joints and other accessories shall give same insulation and weather protection
as for straight pipes.
The insulation system shall fulfil class 1 in
accordance with NT Fire 036.
In addition to what ISO 5660 specifies, concentration of various vapours, fumes and gases shall be documented according to the chemical composition of the material.
For pipe systems with heat tracing a groove (duct) shall be formed in the insulation tight to the main pipe. The groove (duct) shall be dimensioned to allow space for the heating cable and material for the application
4.4 Installation
The Insulation Handbook established by Statoil, Norsk Hydro and Saga may be used to secure a uniform and acceptable design of the insulation work.
4.4.1 General
The insulation materials and the external jacketing shall be installed in such a way that water does not enter the insulation material or between the insulation and the pipe / equipment surface during design life.
Surfaces to be insulated shall be clean and dry. The application of the insulation shall not be started before the mechanical completion certificate for coating has been issued. Surfaces to be insulated shall be treated in accordance with NORSOK M-501.
Discontinued insulation work shall be properly covered to avoid damage and ingress of water to the insulation clean and dry.
Single layer insulation shall be applied with longitudinal joints staggered. In double-layer applications, joints of the outer layer shall be staggered with respect to the inner layer joints. All insulation shall be installed with all joints tightly glued together. Voids within the insulation are not acceptable.
If insulation work precedes testing of pipe work, welds and joints shall be left uninsulated to allow inspection during testing.
Insulation on valves shall leave the packing gland accessible.
To secure cellular glass pre-formed sections in place, adhesive glass fibre reinforced tape or stainless steel banding shall be used. Wire shall not be used.
4.4.2 Pre insulation
The service pipe, insulation and jacket shall be one compact construction. Insulation and jacket must follow the thermal movement of the service pipe. All welding must be controlled, pressure tested, documented, approved and surface treated before the final insulation is performed.
4.4.3 Metallic jacketing
The crimps on jacketing shall have the following minimum dimensions; depending on outside diameter (including insulation):
| Up to 300 mm: | 10 mm | 5 mm radius |
| Between 300 mm and 600 mm: | 13 mm | 6,5 mm radius |
| Above 600 mm: | 16 mm | 8 mm radius |
All jacketing seams shall be installed by roof tile principle and the application of joint sealer shall be inside the jacketing.
Metallic jacketing for vessel insulation shall be edge crimped and overlapped 75 mm on longitudinal and circumferential seams. Vessel jacketing shall be provided with bands on all overlap seams and support rings ( 400 mm c/c ).
Head covers on vessels shall overlap shell covers by 100 mm.
On vessel jackets, breather springs shall be used on bands if required for expansion.
On vertical vessels and piping, "S" clips shall be used to keep the jacket sheets from sliding. Minimum 4 clips per seam.
Metallic jacketing shall be fastened with stainless steel bands. Only for difficult details such as bends, T-pieces etc. pop rivets (or equivalent) may be used.
Metallic jacketing for pipes and fittings shall be roller formed and edge crimped at longitudinal seams. Circumferential seams shall be crimped 50 mm from the edge wherever possible. Circumferential seams shall be overlapped minimum 50 mm. Longitudinal seams for outside diameters up to 150 mm shall be overlapped 30 mm and 50 mm above.
5. HOT SERVICE AND ACOUSTIC INSULATION
5.1 General
This clause describes the requirements for the following insulation classes:
5.2 Design
Guidance for the choice of insulation thickness for heat conservation and personnel protection is for cellular glass given in table 2. If a specific temperature has to be maintained, the thickness of the insulation material in question has to be specified in each case.
The following equipment shall not be insulated for heat conservation class 1 except for steam services or when otherwise specified:
Flanges operating at temperatures above 450 OC shall be insulated and protected with sheet metal jacketing.
5.3 Installation
The following requirements apply in addition to those in clause 4.5
Insulation sections shall be installed according to manufacturers standard procedure.
5.3.1 Block insulation for vessels / cellular glass
Block insulation for vessels:
5.3.2 Blanket insulation on vessels / ceramic fibres / mineral wool
Blanket insulation on vessels:
5.3.3 Prefabricated pipe section insulation / cellular glass / mineral wool
Prefabricated insulation shall be applied as follows:
5.3.4 Blanket insulation for piping / ceramic fibres / mineral wool
Blanket insulation shall be used for dimensions where pipe sections are not available.
5.3.5 Pre insulation for piping
Pre insulation shall be applied as follows:
5.4 Guidance for insulation thickness
Table 1 applies to Heat conservation (class 1) and personnel protection (class 3)
|
DN |
Maximum operating temperatures oC | |||||||
|
mm |
100 |
150 |
200 |
250 |
300 |
350 |
400 |
420 |
|
20 |
30 |
30 |
30 |
30 |
50 |
50 |
50 |
50 |
|
25 |
30 |
30 |
50 |
50 |
50 |
50 |
50 |
50 |
|
32 |
30 |
30 |
50 |
50 |
50 |
50 |
50 |
50 |
|
50 |
30 |
30 |
50 |
50 |
50 |
50 |
80 |
80 |
|
65 |
30 |
30 |
50 |
50 |
50 |
80 |
80 |
80 |
|
80 |
30 |
50 |
50 |
50 |
50 |
80 |
80 |
80 |
|
100 |
50 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
|
150 |
50 |
50 |
50 |
50 |
80 |
80 |
80 |
100 |
|
200 |
50 |
50 |
50 |
50 |
80 |
80 |
80 |
100 |
|
250 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
300 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
350 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
400 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
450 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
500 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
600 |
50 |
50 |
50 |
50 |
80 |
80 |
100 |
100 |
|
Above 600 and flat surface |
50 |
50 |
80 |
80 |
100 |
100 |
100 |
150 |
Table 1. Thickness in millimetres for cellular glass.
The material thickness given above is guidelines only. They shall be adjusted up to the closest standard thickness given by the manufacturer. Thickness of 80 mm and above can be built up in two layers if required.
For other materials or pre insulation the guidelines above may be used to the nearest standard thickness.
5.5 Guidelines for Steam Service and Exhaust Lines
Steam Service and Exhaust lines will normally have an operating temperature enabling
eventual wet insulation to dry out. In such cases mineral wool may be used if accepted by Company.
Steam lines utilising mineral wool pipe sections shall be of nominal density 140 kg/m3. Weather protection shall be stainless steel jacketing.
Exhaust lines utilising mineral wool mattresses shall be of nominal density 105 kg/m3, with galvanised wire mesh at one side. Weather protection shall be stainless steel jacketing.
|
DN |
Steam service |
Turbine exhaust | |||||||||
|
Operating temperatures oC |
Operating temperatures oC | ||||||||||
|
mm |
200 |
250 |
300 |
400 |
200 |
300 |
400 |
500 |
600 |
700 |
800 |
|
25 |
30 |
40 |
50 |
60 |
|||||||
|
38 |
40 |
50 |
50 |
60 |
|||||||
|
50 |
50 |
50 |
60 |
80 |
|||||||
|
80 |
50 |
50 |
60 |
80 |
|||||||
|
100 |
50 |
50 |
70 |
80 |
|||||||
|
150 |
50 |
50 |
80 |
80 |
|||||||
|
200 |
50 |
50 |
80 |
100 |
|||||||
|
250 |
50 |
50 |
80 |
100 |
|||||||
|
300 |
50 |
50 |
80 |
100 |
|||||||
|
350 |
50 |
50 |
80 |
100 |
|||||||
|
400 |
50 |
50 |
80 |
100 |
|||||||
|
450 |
50 |
50 |
80 |
100 |
|||||||
|
500 |
50 |
50 |
80 |
100 |
50 |
100 |
130 |
150 |
175 |
175 |
200 |
|
600 |
50 |
50 |
100 |
100 |
50 |
100 |
130 |
150 |
175 |
200 |
200 |
|
And above |
50 |
50 |
100 |
100 |
50 |
100 |
130 |
150 |
175 |
200 |
200 |
Table 2 Thickness in millimetre for mineral wool
5.6 Class 5, Fire Proofing
The purpose is to reduce the heat input on piping, vessels and equipment in a hydrocarbon fire situation.
If the material strength of equipment will be reduced by being subjected to a fire, this must be taken into account in the evaluations, of regulations relating to explosions and protection of installations in the petroleum activities. With regard to evaluations of depressurising time, a recognised standard such as API RP 521 may be used. If passive fire protection is used, the material strength can be retained for a longer period of time and thereby affect the depressurising time.
Required insulation thickness, and combination of insulating materials, shall be calculated on an individual basis, and the following shall be taken into consideration:
5.7 Guidelines for acoustic insulation
The acoustic pipe insulation classes can be met by various combinations of insulation materials and jacketing systems. Within the same installation one should try to limit the number of pipe insulation systems by choosing alternatives that provides combinations of sufficient personnel protection, heat insulation, cold medium conservation, fire protection and noise insulation when and as required.
Valves and flanges shall be insulated when specified.
Guidelines for the choice of various layers of pipe insulation materials is given in Annex 1:
All systems shall be tested according to approved methods, ref. Annex 2.
All materials shall also be tested and approved in the actual combination. To correct for uncertainties in materials, workmanship and measurements 3 dB shall be subtracted from the measured values.
The following applies to the materials:
6. COLD SERVICE INSULATION
6.1 General
This clause describes the requirements for the following insulation classes:
6.2 Design
If a specific temperature has to be maintained for process reasons, the thickness of the insulation has to be specified in each case.
6.2.1 Vessel insulation
Where required, man ways shall be provided with removable covers of the same insulation thickness as the shell insulation. Covers shall be secured to the shell insulation and sealed to provide vapour tight joints.
6.2.2 Piping insulation
Valves and fittings shall be insulated with pre formed pipe insulation. Sections shall be cut from standard blocks, fitted and wired in place. Alternatively, tailor made jackets may be used.
Flanges shall be insulated with the same insulation thickness as the thickness on adjoining pipe run, vessel, machinery or fitting.
In order to avoid frost formation or condensation on pipe supports, insulated prefabricated pipe supports shall be used.
6.3 Installation
The following requirements apply in addition to those in clause 4.5.
A smooth outer insulation surface must be obtained to provide an effective vapour seal.
6.3.1 Block insulation for vessels
Block insulation for vessels:
6.3.2 Piping insulation
Prefabricated insulation of cellular glass shall be applied as follows:
6.3.3 Pre insulation for piping.
Pre insulation shall be applied as follows:
6.4.3 Guidance for insulation thickness
6.3.4.1 Frost proofing, Class 4 piping and equipment with heat tracing:
Thickness of insulation for piping and equipment shall be:
6.3.4.2 Frost proofing, Class 4 piping and equipment without heat tracing:
Thickness of insulation for piping and equipment shall be:
Table 3 applies to cold service insulation, class 2 and 9, and condensation protection.
|
DN |
Minimum temperatures oC | |||||||||
|
mm |
5 |
0 |
-10 |
-20 |
-30 |
-40 |
-50 |
-60 |
-70 |
-80 |
|
25 |
30 |
30 |
50 |
60 |
60 |
75 |
75 |
90 |
90 |
100 |
|
32 |
30 |
50 |
50 |
60 |
75 |
75 |
75 |
90 |
100 |
100 |
|
50 |
30 |
50 |
50 |
60 |
75 |
90 |
90 |
100 |
100 |
100 |
|
65 |
50 |
50 |
50 |
60 |
75 |
90 |
90 |
100 |
100 |
125 |
|
80 |
50 |
50 |
60 |
75 |
75 |
100 |
100 |
100 |
125 |
125 |
|
100 |
50 |
50 |
60 |
75 |
75 |
100 |
100 |
100 |
125 |
125 |
|
150 |
50 |
50 |
60 |
75 |
90 |
100 |
100 |
125 |
125 |
125 |
|
200 |
50 |
50 |
75 |
75 |
90 |
100 |
125 |
125 |
125 |
150 |
|
250 |
50 |
50 |
75 |
75 |
100 |
100 |
125 |
125 |
150 |
150 |
|
300 |
50 |
50 |
75 |
75 |
100 |
100 |
125 |
125 |
150 |
150 |
|
350 |
50 |
50 |
75 |
75 |
100 |
100 |
125 |
125 |
150 |
150 |
|
400 |
50 |
50 |
75 |
75 |
100 |
100 |
125 |
125 |
150 |
150 |
|
450 |
50 |
50 |
75 |
75 |
100 |
100 |
125 |
150 |
150 |
150 |
|
500 |
50 |
75 |
75 |
75 |
100 |
100 |
125 |
150 |
150 |
150 |
|
600 |
50 |
75 |
75 |
75 |
100 |
100 |
125 |
150 |
150 |
175 |
Table 3. Thickness in millimetres for cellular glass.
The material thicknesses given above are guidelines only. They shall be adjusted up to the closest standard thickness given by the manufacturer. Thickness of 100mm and above can be built up in two layers if required.
For other materials or pre insulation the above guideline may be used to nearest standard calculated according to the thermal conductivity.
7. COMBINATION OF INSULATION CLASSES
7.1 General
Below guidelines are given for insulation systems in cases where insulation shall serve more than one purpose:
Two digits in the line number on the P&ID will indicate the insulation class and the insulation symbol will show insulation material and thickness.
Insulation Class 1 will be shown as 01 etc. Insulation systems with combination of class 1 an 5 can be identified with the two digits 15 in the line number or other project specific combinations.
7.1.1 Fire proofing (5) combined with Heat conservation (1) and or Acoustic insulation (6, 7 & 8).
Use class 5 fire proofing and relevant class for acoustic insulation builds up. Select the thickness from the insulation class with the greatest thickness. Stainless steel jacketing shall be used.
7.2 Acoustic insulation (6, 7 & 8) combined with Heat conservation (1) or Personnel protection (3).
Use Acoustic insulation build up. Select the thickness from the insulation class with the greatest thickness.
7.3 Fire Proofing (5) combined with cold service insulation (2, 4 and 9)
Use cellular glass for the cold service and add a layer with the required thickness of accepted fire protection material. A vapour barrier outside the fire protection to be included to reduce intrusion of water/vapour into the fire protection. Stainless steel jacketing shall be used.
7.4 Acoustic insulation (6, 7 & 8) combined with cold service insulation (2, 4 and 9)
Use acoustic insulation build up, but add an outer layer of cold service insulation. The thickness of the acoustic insulation will allow a similar reduction in the thickness of the cold service insulation. However, minimum thickness of the cold service insulation shall be 30 mm.
8. QUALIFICATION REQUIREMENTS
8.1 Qualification of insulation system
The requirements for qualification prior to use are applicable to insulation
class 5.
The fire resistance shall be decided in accordance with recognised
standards and/or calculation models.
Tests shall be carried out on complete
insulation system installed on a test piece on a relevant dimension.
The
following shall identify the fire technical requirement relating to insulation
materials:
8.2 Qualification of personnel
8.2.1 Qualification of insulation
fitters
Operators shall be qualified to tradesman level as
insulation fitter or sheet metal worker.
The personnel shall have a relevant knowledge of health and safety hazard, use of protection equipment, insulation materials, application of insulation materials, insulation systems surface requirements, and how to avoid corrosion under insulation.
If not qualified to tradesman level, personnel shall be subject to a test in
accordance with this for Standard classes 1, 4 and 5.
The test shall be
supervised by a qualified supervisor and examined by qualified QC personnel.
An examination certificate shall be issued if the candidate passes the test.
Inspection personnel shall have access to site test procedures.
The test shall be carried out on a test piece, composed of a DN 100 pipeline
containing at least one valve, two flanges, one T piece, one trunnion support
and one standard clamped support.
Both valve box and one flange shall be
insulated with AISI 316 material to insulation system
Class
5.
Alternatively a suitable location on the installed pipelines, which as a
minimum consist of the same parts as described for the test piece, may be
selected to which the Insulation Procedure Test (IPT) shall be carried out
8.2.2 Qualification of Supervisors, Foremen and QC personnel
Personnel carrying out inspection or verification shall be qualified to tradesman level and shall be accepted as inspector by company.
Supervisors and foremen shall be qualified to tradesman level and shall have documented minimum 3 years experience with insulation work corresponding to work described in this standard.
All QC- and supervision personnel shall be familiar with the requirements in this standard.
8.3 Qualification of procedures
8.3.1 Insulating Procedure Specification (IPS)
A detailed IPS based on the requirements of this standard shall be established. The IPS shall as a minimum contain the following:
The qualified IPS shall be followed during all insulation work
Following changes in the insulation application parameters requires the IPS
to be re-qualified:
8.3.2 Insulation Procedure Test (IPT)
An IPT shall be used to qualify all insulation procedures. A test piece (ref.
8.2.1 as applicable), alternatively a suitable location on the lines to be
insulated, may be selected to which the IPT shall be performed.
The IPT
shall be qualified under realistic conditions likely to be present during
insulation installation.
Inspection requirements for the IPT shall be as
given in clause 9 and the inspection plan in IPS.
9. INSPECTION AND TEST
Work during production, at delivery and all other pertinent phases, shall be duly inspected.
Reasonable access to workshop and personnel for inspectors shall be allowed for.
Inspection shall be carried out at each stage of the work, but as a minimum before second layer of multi layer insulation is applied and before jacketing is applied.
ANNEX A - TO NORSOK STANDARD R 004
| Insulation class | Insulation Materials | Jacket Material |
Other Comments /
Build-up |
| Class 1 Heat Conservation |
Cellular glass Mineral wool at temp. higher then 420 OC |
Non-metallic weather-proofing membrane., or Stainless Steel / Al | |
| Class 2 Cold Service Insulation |
Cellular glass | Non-metallic weather-proofing membrane., or Stainless Steel / Al | Vapour barrier |
| Class 3 Personnel Protection |
Either: Class 1 9 Or Perforated sheet metal guards |
In accordance with classes 1 9 as applicable | Perforated guards to be of stainless
steel. If insulation is used, it shall be designed so that the jacket temperature do not exceed 70 OC |
| Class 4, Frost Proofing |
Cellular glass | Non-metallic weather-proofing membrane., or Stainless Steel / Al | Vapour barrier |
| Class 5, Fire proofing |
Cellular glass + Ceramic fibre or mineral wool when necessary |
Stainless steel | Insulation materials are dependant on protection requirements, and must be accepted in writing by client for each case |
| Class 6, Acoustic Insulation 10dB |
Cellular glass Ceramic fibre or Mineral wool Heavy synthetic sheet |
Non-metallic weather-proofing membrane., or Stainless Steel / Al | 30mm Cellular glass + 25mm "fibres" + metallic jacketing (or aluminium foil + non-metallic jacketing) |
| Class 7, Acoustic Insulation 20dB |
Cellular glass Ceramic fibre or Mineral wool Heavy synthetic sheet |
Non-metallic weather-proofing membrane., or Stainless Steel /Al | 30mm Cellular glass + 38mm "fibres" + heavy synthetic sheets + metallic jacketing (or aluminium foil + non-metallic jacketing) |
| Class
8, Acoustic Insulation 30dB |
Cellular glass Ceramic fibre or Mineral wool Heavy synthetic sheet |
Non-metallic weather-proofing membrane., or Stainless Steel /Al | 30mm Cellular glass + 38mm "fibres" , + 2 x heavy synthetic sheets + 25mm fibres + 2 x heavy synthetic sheets + metallic jacketing (or aluminium foil + non-metallic jacketing) |
| Class 9, External Condensation |
Cellular glass | Non-metallic weather-proofing membrane., or Stainless Steel /Al | Vapour barrier |
These key data are not applicable for pre insulated pipe systems.
ANNEX B - TO NORSOK STANDARD R 004
INSERTION LOSS - TEST PROCEDURE
General
The acoustic properties of pipe insulation can be characterised by the insertion loss. Today, there are no national or international test standards established for such measurements. This attachment describes a "survey" method for measuring the acoustic insertion loss of pipe insulation systems. This method should be used to determine the "Classes of Acoustic Pipe Insulation" as defined in NORSOK R-004, rev. 2.
Frequency dependent Insertion Loss
The frequency dependent insertion loss is defined by the following equation:
ILi = LpU, i - LpI, i
ILi : Insertion loss at the frequency "i"
LpU : Reference measurement of the bare pipe. The noise level at 1,0 m distance from the uninsulated pipe, calculated as the logarithmic average of all microphone positions.
LpI : Measurements of the insulated pipe. The noise level, logarithmic average, in the same microphone positions after the insulation system is applied.
Although the acoustic classes of insulation are described by a single value derived from the three 1/1-octave band levels 500, 1000 and 2000 Hz, measurements should be performed in 1/3-octave bands in a broader frequency range. This will provide important additional information to be used in predictions of sound radiation from various pipelines.
For all other measurements than site tests, measurements shall be performed in 1/3 octave band levels and as a minimum cover the frequency range of 100-5000 Hz.
ACOUSTIC CLASSES - Average insertion loss
The acoustic insulation is defined as the arithmetic average of the insertion loss in the three
1/1-octave bands with centre frequencies at 500, 1000 and 2000 Hz:
IL = (IL500 + IL1000 + IL2000)/3
The 1/1-octaveband levels shall be calculated from the measured 1/3-octaveband levels after a linearisation of the reference spectrum (LpU) - i.e. a correction shall be added or subtracted to the LpU,i-values to obtain a "flat" (linear) spectrum. The LpI,i-values shall be adjusted correspondingly.
3 dB shall be subtracted from the calculated average insertion loss (IL), before defining the acoustic class of the pipe insulation as described in NORSOK R-004.
Test arrangement
A pipe of at least 5 metre length should be used for the test. The pipe diameter should be in the range of 200 - 400 mm, and the pipe wall should have a thickness of 8 12 mm.
If the normal pipe diameter that the insulation will be used for is outside than this range, the system may be tested for the relevant diameter. Considerations about the effect of other dimensions should be given in the test report.
The pipe may be set into vibration in several ways. For a survey purpose it may be unfeasible to use a "natural" source like for instance the noise from a valve for the test, unless there is a suitable test spot within a process area, which can be screened of from other sources.
A sound source of appropriate power to create sufficient high noise level in the pipe may therefore be used. The source must be placed in separate room or an insulated enclosure (box) with sufficient sound insulation to prevent false noise to interfere with the measurement results.
The measurements may be performed in a reverberant room, a semi reverberant soundfield or in free field conditions. The number of measurement positions should then be at least 5 randomly distributed at for instance 1 metre distance from the bare pipewall. The sound pressure measurements and averaging of the noise levels should be performed in accordance with recognised standards for such measurements. Methods described in ISO 3740 3746 and
ISO 11200 11204 may be used as reference for calibration, measuring technique, microphone positions, requirements to and influence of background noise, environmental contribution form the test place (room), etc. If intensity measurements are used in stead of measurements in discrete positions the relevant intentional standard shall be given, for instance ISO 9614-2.
The noise from the source shall enter the measurement site mainly through the pipe wall, also after the pipe insulation has been applied to the pipe. Both the source end of the pipe and the opposite end (passive end) must therefor be insulated sufficiently to reduce the contribution from these sources to an insignificant level.
Measurement procedure
A system to check the "sound source" should be established in order to ensure a constant excitation during the test. This may for instance be a microphone placed at a fixed position inside the pipe.
A calibration test of the instrumentation shall be carried out before and after the test. The microphone positions must be kept at the same places; to ensure that environmental reflections contributes similarly to the measured levels through all series of measurements.
The background sound level must be checked, and if the level is within 10 dB below the lowest noise level from the pipe, the measured levels shall be adjusted. Background levels which is less than 5 dB below the lowest 1/3 octaveband levels should not be accepted.
During the test one should also check any influence from "false" sources such as leaks, radiation from supports, radiation from pipe ends, radiation from source room etc.
Report
The following should be reported from the test:
Test arrangement
Measurement procedure
Materials tested
Test results